PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
WTB (Wired Train Bus) Cables
FRL-WTB-02YCH-2G0.75, FRL-WTB-02YCH-1P0.75S, FRL-WTB-02YCH-2P0.75S
A. Conductor B. Insulation C. Screen D. Sheath
Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB (Multifunction Vehicle Bus) which are connected via redundant gateways.
Construction
Conductors
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam PE or Foam Skin
Core Wrapping
Plastic tape(s)
EMC Screen
Tin plated copper braid
Outer Sheath
Cross-linked oil resistant LSZH compound
Electrical & Mechanical Properties
Nominal Voltage 300V
Maximum Temperature 100°C
Minimum Temperature -40°C
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
Fire Performance for rolling stock application
EN 50306-2 | Hazard levels HL1, HL2, HL3 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN45545-2 |
R15 Interior/ R16 Exterior HL1, HL2, HL3 |
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-WTB-02YCH-2G0.75
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Transfer Impedance | Maximum Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|---|
20℃ | @1-10MHz | f<=30MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | mΩ/m | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.4 | 8.3 | 97 | 26.7 | 120+/-12 | 30 | 10 | 13 | 14 | 18 |
FRL-WTB-02YCH-1P0.75S
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Transfer Impedance | Maximum Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|---|
20℃ | @1-10MHz | f<=30MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | mΩ/m | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.4 | 9.0 | 110 | 26.7 | 120+/-12 | 30 | 10 | 13 | 14 | 18 |
FRL-WTB-02YCH-2P0.75S
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Transfer Impedance | Maximum Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|---|
20℃ | @1-10MHz | f<=30MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | mΩ/m | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.4 | 11.4 | 150 | 26.7 | 120+/-12 | 30 | 10 | 13 | 14 | 18 |